3BHE030410R3011 – Alternative Names:
Excitation system control and management core component 3BHE030410R3011
3BHE030410R3011 Excitation Central Processing Unit
ABB Relion® 670 Series Excitation Controller 3BHE030410R3011
I. Operating Principle
The 3BHE030410R3011 is the core high-speed central processing unit for
synchronous generator excitation systems based on the AC800PEC platform. It
serves as the master control core of the UNITROL excitation control system,
handling closed-loop excitation regulation, protection logic, signal
acquisition, and external communication.
Signal Acquisition: The module performs high-speed acquisition of analog
and digital signals—such as generator terminal voltage, stator current,
excitation current, rotor temperature, active/reactive power, and grid
frequency. It features a built-in high-precision ADC to handle signal
conditioning, sampling, and filtering.

High-Speed Closed-Loop Control Computation: Leveraging the high-speed
core of the AC800PEC, it executes multi-mode control algorithms—including AVR
(Automatic Voltage Regulator) PID control, reactive power regulation, power
factor regulation, and constant excitation current regulation. With control
cycles reaching the microsecond range, it rapidly calculates trigger control
commands for the thyristor rectifier bridge and outputs pulse reference signals
to the power unit. It supports automatic code generation from MATLAB/Simulink
models and allows for the embedding of Power System Stabilizer (PSS) algorithms
to suppress low-frequency oscillations and enhance grid damping. Protection
Logic: Incorporates a comprehensive suite of protection criteria for the
excitation system, including over-excitation, under-excitation, V/Hz limiting,
rotor overcurrent, loss-of-field protection, and load rejection protection. It
performs real-time fault diagnosis and immediately issues trip and
field-suppression commands when protection thresholds are triggered.
Communication and Data Exchange: Integrates interfaces such as Ethernet,
RS232/485, and Profibus. It communicates upstream with the power plant DCS and
HMI to upload unit operating status and waveform recording data, while
interacting downstream with excitation I/O modules and power rectifier units. It
supports fault recording, capturing waveforms throughout the entire disturbance
process for accident analysis.
Redundancy Mechanism: Supports a dual-controller redundancy configuration
(primary/standby CPU). In the event of a primary module failure, it performs a
bumpless transfer to the standby module, ensuring uninterrupted excitation
regulation and meeting the requirement that large generator units must not
suffer from single-point failures in the excitation system.
Summary: Acquires real-time electrical parameters from the generator and
grid → Executes high-speed AVR, PSS, limiting, and protection algorithms →
Outputs trigger commands to control the excitation power circuit → Handles data
uploading, fault alarming, and redundancy switching.
II. Application Areas
This module is designed for use with ABB UNITROL excitation systems.
Leveraging the high-speed control capabilities of the AC800PEC, it is primarily
used for the excitation regulation of synchronous generators:
Thermal/Gas Combined-Cycle Power Plants: Excitation for steam turbine and
gas turbine generators; manages rapid load fluctuations and grid disturbances;
ensures compliance with grid connection codes; utilizes PSS to suppress power
oscillations.
.jpg)
Hydropower Plants: Hydro-generator units; adapts to variations in water
head and severe load rejection conditions; supports both isolated grid and
grid-connected operation.
Industrial Captive Power Plants: Synchronous generator units for steel,
chemical, and paper enterprises; ensures stable power supply for plant
operations. Diesel Synchronous Generator Sets: Excitation for large-scale
emergency diesel generators, islanded power supply, and black-start
scenarios.
Synchronous Condensers for New Energy Applications: Excitation control for
synchronous condensers, providing reactive power support and voltage stability
for the grid.
High-Power Marine Synchronous Generators: Excitation for marine power
plants, capable of handling sudden load fluctuations in shipboard power
grids.
Positioning: Suitable for excitation system retrofits and new installations
of medium-to-large synchronous generators requiring high control response
speeds, reliable protection, and robust grid adaptability.
III. Environmental Conditions (Cabinet-mounted)
Operating Temperature: 0°C to +55°C; for long-term full-load operation,
keeping the temperature below 45°C is recommended. Temperatures above 55°C
accelerate chip aging and reduce MTBF; temperatures below 0°C require internal
cabinet heating.
Storage Temperature: -40°C to +85°C.
Relative Humidity: 5% to 95%, non-condensing; condensation inside the
cabinet is strictly prohibited, as it can cause short circuits on circuit boards
and PCB corrosion.
Vibration and Shock: Compliant with IEC 60068; requires reinforced cabinet
mounting; avoid proximity to strong vibration sources such as high-power
contactors or rectifier transformers.
Atmospheric Environment: The air must be free from corrosive gases
(hydrogen sulfide, chlorine), conductive dust, and salt spray; cabinets located
in coastal or chemical industrial areas require air filtration and salt-spray
protection measures.
Electromagnetic Environment: Install within a metal control cabinet with
reliable grounding; route wiring separately from thyristor power circuits to
avoid strong electromagnetic interference. Protection Rating: IP20 (for internal
cabinet use only; not suitable for exposed field installation). IV. Module
Advantages
High-Speed Control Performance: The AC800PEC platform features a
microsecond-level control cycle, offering faster response times than traditional
excitation controllers. It delivers superior dynamic voltage performance during
grid disturbances and load rejection events and supports embedded PSS and
multi-limiter coordination algorithms.
Flexible Control Modes: Supports multiple regulation modes—including
constant terminal voltage, constant excitation current, constant reactive power,
and constant power factor—with seamless switching. It supports model-based
development, enabling automatic control code generation via Simulink and
facilitating convenient algorithm iteration.
Comprehensive Built-in Protection & Waveform Recording: Includes a full
suite of excitation limiting and protection logic, as well as integrated fault
waveform recording; no additional recording devices are required, simplifying
fault analysis and traceability.
High Redundancy and Reliability: Supports dual-CPU redundancy and redundant
power supplies with bumpless switchover between primary and backup units,
meeting reliability requirements for critical power plant equipment.
.jpg)
Open Communication Architecture: Supports multiple protocols, facilitating
integration with DCS, SIS, and power plant monitoring systems for remote
monitoring and parameter tuning.
Modular Architecture: I/O, communication, and power supply components are
independent modules; localized faults require only the replacement of the
specific module, simplifying maintenance and reducing downtime.
Strong Grid Adaptability: Meets rigorous domestic and international
grid-connection standards, maintaining unit stability during grid low-frequency
oscillations and voltage dips.
V. Installation, Commissioning, and O&M Considerations
Hardware Installation
Modules must be inserted or removed only when power is disconnected;
hot-swapping CPU boards is strictly prohibited, as it can easily damage the
backplane bus and chips.
Cabinet grounding must be reliable, utilizing single-point grounding for
both protective earth and signal ground. High-voltage cables (excitation power
lines) must be routed in separate cable trays from low-voltage signal and
communication cables to prevent interference that could cause AVR instability or
spurious protection trips. Ensure module backplanes and terminals are securely
fastened; avoid impacts during transport and installation. Circuit boards are
sensitive to static electricity; anti-static wrist straps must be worn during
handling.
Keep cooling air ducts unobstructed and clean dust filters regularly;
continuously monitor temperature and humidity inside the cabinet to prevent
condensation.
Commissioning and Parameters
Verify the firmware version before powering up; the version must be
compatible with the entire UNITROL excitation system software suite. Mismatched
versions can lead to communication anomalies and protection logic errors.
Excitation parameter setting must be performed in stages: first, statically
verify acquisition circuits; next, conduct no-load tests; then, proceed to load
tests and PSS parameter tuning. Strictly prohibit arbitrary modification of
protection settings or AVR parameters while grid-connected, as this can cause
generator instability or over-excitation incidents.
When commissioning redundant systems, perform separate primary/backup
switchover tests to verify that the switchover process causes no excitation
disturbances.
Operation and Maintenance
Regularly check module status indicators to monitor the CPU, power supply,
communication, and fault alarm status; periodically export waveform logs to
troubleshoot latent anomalies.
Circuit boards are precision electronic components subject to aging during
long-term operation; stock spare parts in advance. Do not use non-OEM
refurbished boards for direct operation.
After replacing a faulty module, download the project configuration, verify
parameters, and complete functional tests (drive tests); ensure protection and
regulation functions are normal before putting the unit back into service.
Software modifications and firmware upgrades must be performed while the
unit is shut down or safely isolated; create a full backup of the project
program before upgrading.
Electromagnetic interference: If voltage sampling fluctuates or random
false alarms occur, prioritize checking shielding grounds and ensuring cable
shields are grounded at a single point; investigate electromagnetic noise
originating from the excitation power cabinet.
Safety Red Lines
Do not open the CPU module cover plate while the excitation system is
energized or when the generator is ready for field flashing (excitation
startup). Any modification to protection settings must be carried out in
accordance with the work permit and dual-verification procedures.
If a module reports a hardware fault, it is recommended to switch to manual
excitation mode or shut down the unit for inspection; prolonged operation with a
known fault is prohibited.
Related product recommendations:
PPD512A10-15000 3BHE040375R1023
PPD512A10-454000 3BHE040375R103E
PP D513 A0C-110440 3BHE039724R0C4A
3BHE041576R3011 PPD517A3011
3BHE051476R3011 PPD517
3BHE041576R3011 PPD517
3BHE041576R3011 PPD517
PPD539A 3BHE039770R0102
PPD539A102 3BHE039770R0102
GFD212A 3BHE020357P201
3BHE020356R0101 GFD212
3BHE022294R0101 GFD233
3BHE022294R0103 GFD233
3BHE046836R0101 GFD563
3BHE046836R0102 GFD563A102
ABB 5SHY35L4503
3BHE031197R0001 GBU72
3BHE055094R0002 GBU72
L003748-AR ABB-3BSX108237R300
5SGY3545L0010 3BHB006485R0001
5SHY35L4503 3BHB004692R0002
More......