3EST000212-0728 | PLC I/O and Output Modules | Bombardier | 3EST000212-0728

It adopts DIN rail mounting and is directly fixed to a standard DIN rail with screws. The module has a bus connector on the back, which automatically establishes bus communication after being inserted into the CPU module backplane. The front end uses plug-in terminal blocks (20 pins for 16-point modules, 40 pins for 32-point modules). When wiring, first connect the wire to the terminal block, then insert the connector into the module, ensuring the coding elements engage—this design guarantees that the connector can only be inserted into the corresponding type of module, preventing mis-insertion.

  • Description
  • Reviews

  Many products are not yet listed. Please contact us for more product information.

  If the product model differs from the displayed image, the model number shall prevail. Please contact us for specific product images; we will arrange to take photos in our warehouse for confirmation.

  We have 76 shared warehouses worldwide, so it may sometimes take several hours to return an accurate result. We apologize for any inconvenience. Of course, we will respond to your inquiries as soon as possible.


  Other names for 3EST000212-0728:

  Digital Module 3EST000212-0728

  3EST000212-0728  Analog Module

  467 Type Socket Module  3EST000212-0728

  I. Product Overview

  The 3EST000212-0728 is a programmable logic controller (PLC) designed by Bombardier Transportation specifically for rail transit signal control systems. It belongs to the GE Fanuc/Honeywell DCC (Distributed Control Center) series architecture. This controller is widely used in interlocking systems, ATS (Automatic Train Control) systems, and turnout control systems for subways, light rail, and intercity railways.

  Controller Features:

  Processor: 32-bit RISC architecture CPU

  Program Memory: Expandable to 256K words

  Scan Cycle: Typical 10~50 milliseconds

  Communication Interfaces: Dual redundant Ethernet, DeviceNet, RS-232/485

  Power Supply: Dual redundant hot standby power supply module

  Installation Method: DIN rail mounting, standard 19-inch rack


  II. I/O Module Architecture

  1. Digital Input Module (DI Module)

  The digital input module receives switching signals from field devices, converts them into low-level signals that can be processed internally by the PLC, and provides electrical isolation.

  Input Signal Type: Dry contact (passive contact) or 24VDC active signal

  Isolation Method: Optocoupler isolation

  Typical Point Configuration: 8 points, 16 points, 32 points

  Common Terminal: All channels share a common terminal (COM), which is divided into positive common (PNP type) and negative common (NPN type) depending on the model.

  Application Scenarios: Receiving signals from buttons, limit switches, proximity switches, relay contacts, track circuit status, etc.

  2. Digital Output Module (DO Module)

  The digital output module transmits the binary control signals from the PLC to the field actuators.

  Output Type 1 – Relay Output

  Contact Type: Normally Open (NO) Dry Contact

  Load Capacity: AC 250VAC/5A or DC 30VDC/5A (typical)

  Applicable Loads: Solenoid valves, indicator lights, relay coils, contactors, etc.

  Features: AC/DC compatible, good isolation, but slow response time (approximately 10ms)

  Output Type 2 – Transistor Output

  Output Type: NPN (sink) or PNP (source)

  Typical Voltage: 24VDC

  Load Capacity: Approximately 0.5A per point

  Applicable Loads: LED indicators, small solenoid valves, intermediate relays, etc.

  Features: Fast response time (microseconds), suitable for high-frequency applications

  Output Type 3 – Triac/SCR Output

  Applicable Voltage: AC 120V/230V

  Applicable Loads: AC solenoid valves, AC contactors, heaters, etc.

  Features: Contactless switch, long lifespan, suitable for AC loads

  3. Analog Input Module (AI Module)

  Signal Types: 4-20mA current signal, 0-10V voltage signal, thermocouple (TC), resistance temperature detector (RTD)

  Accuracy: 12-bit or 13-bit A/D conversion

  Number of Channels: Typically 4, 8, or 16 channels

  Isolation: Electrical isolation between analog side and CPU side

  Applications: Continuous signal acquisition such as temperature measurement, pressure transmitters, and speed sensors

  4. Analog Output Module (AO Module)

  Output Signal: 4-20mA or 0-10V (Programmable Setting)

  Accuracy: 12-bit or 13-bit D/A Conversion

  Number of Channels: Typically 4 or 8 channels

  Applications: Controlling valve opening, inverter setpoint, proportional valve drive, etc.


  III. Typical I/O Configuration (Rail Transit Interlocking System)

  Module Type Typical Model Format Number of Points/Channels Voltage Rating Remarks

  Digital Input 3EST13-DIxx 8/16/32 points 24VDC Optocoupler Isolated, Dry Contact/Active Selectable

  Digital Output (Relay) 3EST13-DOxx-RL 8/16 points AC250V/DC30V Relay Contacts Outputs

  Digital Outputs (Transistors): 3EST13-DOxx-TR8/16-point 24VDC NPN/PNP selectable

  Analog Inputs: 3EST13-AIxx4/8-channel 4-20mA/0-10V, supports TC/RTD

  Analog Outputs: 3EST13-AOxx4/8-channel 4-20mA/0-10V, current/voltage adjustable

  Communication Module: 3EST13-COMM—RS485/Ethernet for inter-station communication

  Power Supply Module: 3EST13-PS—24VDC/110VDC, powers I/O modules

  Power Supply Module 3EST125-970 Dual AC220V input, 5V/24V output

  CPU Module 3EST13-147 Main controller, for program execution

  DO Module 3EST125-975 32-point relay output, drives signals and switches

  DI Module 3EST125-977 32-point digital input, acquires section and switch status

  AI Module 3EST125-976 8-channel analog input, acquires power supply voltage

  AO Module 3EST125-974 8-channel analog output, adjusts signal brightness

  High-speed counting module 3EST125-978 4-channel axle counter pulse counting

  Safety input module 3EST125-980 8-point safety input, connects to emergency stop button

  Safety output module 3EST125-979 4-point safety output, drives safety relays

  DeviceNet Module 3EST125-972 Connects to Remote I/O Stations

  Ethernet Module 3EST125-981 Connects to ATS and Maintenance Terminals


  IV. System Features of BOMBARDIER 3EST Series PLCs

  Redundant Architecture: The 3EST13 series typically employs a dual-CPU hot-standby redundant design to ensure high availability of the signaling system.

  Safety Level: Meets the SIL4 safety integrity level requirements for railway signaling systems.

  Rack Mounting: Modules are mounted on standard DIN rails or dedicated racks, supporting hot-swapping.

  Communication Interface: Supports internal bus communication and external Ethernet/RS485 communication.

  Diagnostic Functions: Each I/O module has LED status indicators (power indicator, channel status indicator) for easy on-site troubleshooting.


  Wiring and Installation Precautions

  First, regarding digital input wiring:

  The common terminal COM of the input module must be correctly connected according to the output type of the field device. If using a PNP sensor (source output, 24V high-level active signal), connect COM to 0V; if using an NPN sensor (sinking output, 0V low-level active signal), connect COM to 24V. Incorrect connection will cause all input points to be either always OFF or always ON.

  Second, regarding digital output wiring:

  The COM terminal of the relay output module must be connected to the positive terminal of the load power supply (for DC loads) or the live wire (for AC loads). Each output group's eight points share one COM terminal and one fuse. If an output point is short-circuited, only the fuse in that group will burn, without affecting other groups. The fuse is a 5A fast-blow fuse, which can be replaced on the front panel.

  Third, regarding analog module wiring:

  The analog input signal lines must use shielded twisted-pair cable, with the shield grounded at one end (grounded on the module side). Shielded cable is also recommended for analog output lines. Do not short-circuit the input terminals in voltage input mode; do not open-circuit the input terminals in current input mode. When inserting the range card, ensure it is fully seated; a "click" sound indicates it is locked.

  Fourth, regarding safety modules:

  Safety input and safety output modules must be used in pairs, and the drive for the safety output must be a safety relay (such as a Siemens SIRIUS 3SK series or Pilz PNOZ series); it cannot directly drive a regular actuator. Diagnostic information from the safety modules must be connected to the CPU for real-time monitoring. Any failure in a safety channel should cause the system to enter a safe state.

  Fifth, regarding module replacement:

  All modules use a coded front connector design. The connector shape and pin definitions vary depending on the module type, making it physically impossible to insert an incorrect module. When replacing a module, first disconnect the power, unplug the front connector of the old module, and align and insert the connector of the new module; no rewiring is required. However, it is recommended to record the wiring labels of each connector before disconnecting the power.


  Diagnosis and Maintenance

  The  3EST000212-0728 CPU provides comprehensive online diagnostic functions:

  Each module's front panel has three LEDs: PWR (Power), RUN (Run), and FAULT (Fault).

  The CPU polls the status of each module via the backplane bus; any module fault will display a fault code on the CPU panel.

  Detailed module diagnostic information, including channel-level fault location, can be read via a maintenance terminal connected via Ethernet.

  Digital input modules can detect open circuit faults (errors occur when the input terminal is floating).

  Digital output modules can detect load short circuits and open circuit faults.

  Analog modules can detect signal over-range faults, sensor open circuits, etc.

  All diagnostic information is timestamped for easy post-analysis analysis.


  The Bombardier 3EST000212-0728 PLC is a complete control platform designed specifically for rail transit safety-critical systems. Its I/O modules cover a full range of requirements, from basic digital to high-precision analog, and from general I/O to SIL4 safety I/O. The fail-safe features of the relay output module, the redundant diagnostic mechanism of the safety module, and the multiple communication interfaces of DeviceNet/Profibus/Ethernet ensure that it fully meets the stringent requirements of EN 50128 and EN 50129 standards for railway signaling systems. All modules adopt the DCC series architecture, and the front connector coding error-proof design greatly reduces the risk of field wiring errors and improves system maintainability.

1.Do you offer global shipping?

Yes. We have local distribution centers on every continent, enabling us to quickly ship parts to anywhere in the world.

2. What payment methods and currencies do you accept?

To make your purchasing process as simple and convenient as possible, we offer a variety of payment methods, including bank transfer, cheque, and PayPal. We also accept most major credit and debit cards, such as Visa, Mastercard, and American Express. We accept payments in most major global currencies, but we recommend using US Dollars (USD), British Pounds (GBP), or Euros (EUR). Using other currencies may incur additional fees. All transactions are securely processed by HSBC and HSBC Merchant Services.

3.How much parts do you currently have in stock?

We have a vast inventory of new, refurbished, and used automation components, including products from well-known manufacturers such as ABB and Schneider Electric. If you can't find the part you need, don't worry. We work closely with professional suppliers worldwide, and even if the part you need isn't listed on our website, we can provide you with a tailored quote.

4.Who should I contact if I encounter any problems?

Our experienced customer service team will handle any issues after you place your order.

Your email address will not be published. Required fields are marked *
Your rating*
Name*
Email*
Code*
Your review*
Save my name,email,and website in this browser for the next time|comment.
Recommended products
Our website uses cookies to ensure you have the best experience, you are agreeing to our use of cookies in accordance with our Cookie Policy.
Online Message
Online
Message
  • home
  • message
  • tel
  • Email
  • top